Fire hazard of Aluminum Composite Panels (ACPs)

26-02-2025 | Posted by Joaquín Martí

Peligrosidad de incendio de los Paneles Compuestos de Aluminio (ACP)

ACPs have been manufactured since the 1970s and used as external cladding in building construction since the late 1980s. They offer advantages like relatively low cost, good insulation, ability to withstand the elements, light weight, easy installation, good mechanical properties, ease of cleaning, and varied and attractive finishes.

However, they may pose a significant fire hazard primarily due to their combustible core materials. ACPs are made up of two thin layers of aluminum sandwiching a core material. The fire risk of ACPs is largely determined by the core material used, which can be broadly categorized into:

  1. Polyethylene (PE) core. Highly flammable, panels with a PE core are particularly hazardous in the event of a fire. Being a thermoplastic, it can melt, ignite, drip, and propagate fire rapidly. Once ignited, it can contribute to the effects of the fire by releasing toxic smoke and heat.
  2. Fire-Retardant (FR) core. Less combustible, panels with an FR core (usually minerals such as aluminum hydroxide or magnesium hydroxide) are designed to slow the spread of fire. Although not completely fireproof, ACPs with an FR core offer significantly better fire resistance.
  3. Non-Combustible (A2) core. Non-combustible cores, often made of high mineral content, can prevent fire spread almost entirely. These panels are typically classified as A2 under European fire ratings, meaning they are highly resistant to fire and contribute minimally to fire growth. However, they are more expensive.

ACPs with PE cores can allow fire to spread quickly across a building’s exterior. Also, when exposed to heat, the plastic core of ACPs can melt and drip, spreading flames to lower floors. Moreover, burning ACPs, especially those with PE cores, release harmful gases like carbon monoxide and hydrogen cyanide, affecting occupants and firefighters.

Following tragic incidents, many countries have implemented stricter fire safety regulations to limit or ban the use of combustible ACPs in high-rise buildings. Some have mandated the use of non-combustible or fire-retardant core materials in facades. For example, within weeks of the Grenfell Tower Fire in 2017, which caused 72 casualties, the UK required all registered owners to identify all buildings with ACPs more than 18 m high; and, in 2019, the government announced it will fully fund the removal and replacement of unsafe ACM cladding on private sector residential buildings higher than 18 m.

Other high-profile fire disasters are:

  • The Lacrosse Building (Melbourne, Australia, 2014). A fire broke out on the balcony of an apartment on the 8th floor. The fire reached the top floors of the 21-story building within minutes, aided by the flammable ACP cladding. There were no deaths, but over 400 residents were evacuated, and the building sustained significant damage. It prompted stricter fire safety standards for buildings in Australia, and the cladding was eventually removed and replaced.
  • Torch Tower (Dubai, UAE, 2015 and 2017). The first fire at the 86-story Torch Tower started on the 50th floor and the cladding’s combustible core allowed it to climb to the top floors within minutes. A second fire occurred just two years later, again spreading quickly. No fatalities were reported, though thousands of residents were evacuated, and the building suffered extensive damage. Dubai authorities implemented stricter fire regulations and banned the use of flammable cladding materials like PE-core ACPs.
  • Address Downtown Hotel (Dubai, UAE, 2015). On New Year’s Eve, a fire broke out on the 20th floor of the 63-story Address Downtown Hotel. The flames quickly spread upwards via the building’s ACP cladding with a PE core. The fire engulfed much of the building’s facade, 16 people sustained minor injuries, and the hotel was closed for repairs for over two years.
  • Tamweel Tower (Dubai, UAE, 2012). The 34-story Tamweel Tower caught fire after a cigarette was discarded into debris near the building. The fire ignited the building’s ACP cladding with a combustible core, and flames spread rapidly across the facade, severely damaging the building. No fatalities were experienced, but residents were displaced for years.
  • Neo200 Building (Melbourne, Australia, 2019). A fire broke out on the 22nd floor of the Neo200 apartment tower. The building’s ACP cladding, which contained a PE core, allowed the fire to spread rapidly to five other floors. No fatalities were reported, but residents were displaced, and the building sustained serious damage.
  • Plasco Building (Tehran, Iran, 2017). The Plasco Building, a 17-story commercial high-rise, caught fire and the flammable ACP cladding accelerated the fire spread, which resulted in 16 firefighter deaths and many injuries. The building collapsed completely within hours.
  • In February 2024, a devastating fire broke out in a high-rise residential building in the Campanar district of Valencia, Spain. The fire engulfed the 14-story complex, resulting in at least 10 fatalities.

Such examples illustrate how combustible ACPs, particularly those with PE cores, have contributed to the spread of fires in buildings worldwide. As a result, many countries have revised their building regulations to restrict or ban the use of ACPs with flammable cores in high-rise buildings.

Existing buildings with flammable ACP cladding can be retrofitted by replacing combustible panels with safer alternatives, which is a costly solution. Another possibility is to install firebreaks between sections of ACP cladding to interrupt flame progression along the facade.

Principia has gathered experience by studying fire hazard, vulnerability and risk, as well as the consequences of fires in buildings and other structures, thereby contributing to improving their fire safety.